NIC’S - SYSTEMS & ELECTRIC
Приєднався 8 кві 2015
Welcome to my channel! My name is Nic and I feature on my UA-cam channel Fire alarm, Security, Electrical, Access control, Life safety systems and more! I post videos every I will try my best to post weekly on Saturday and Wednesday if there are any extra videos they will be posted on Monday. On my channel I share my interests and work I perform in the field. working on fire alarm, electrical and other life-safety systems. I live in canada and work with my school district electrical department. Hope you enjoy my videos!
Home Fire Alarm System Set Off | Two Alarm With Pre-Alarm Smoke Detector Activation
Home Fire Alarm System Set Off | Two Alarm With Pre-Alarm Smoke Detector Activation
Переглядів: 2 342
Відео
The Generator Building Is Too Hot, Fire Alarm Supervisory! Fixing Ventilation System.
Переглядів 3,9 тис.9 годин тому
The Generator Building Is Too Hot, Fire Alarm Supervisory! Fixing Ventilation System.
How to Wire Fire Alarms Without Panel! Wire Heat Detectors, Smoke Detectors & Pull Stations to Alarm
Переглядів 5 тис.День тому
How to Wire Fire Alarms Without Panel! Wire Heat Detectors, Smoke Detectors & Pull Stations to Alarm
Elementary School Loses Power! | Single Phasing Power Outage Two Phases Out 75% Power Gone
Переглядів 14 тис.14 днів тому
Elementary School Loses Power! | Single Phasing Power Outage Two Phases Out 75% Power Gone
Installing Emergency Light Remote Head.
Переглядів 6 тис.14 днів тому
Installing Emergency Light Remote Head.
Pulling The Fire Alarm At My School For The Last Time Ever For Fire Drill
Переглядів 11 тис.21 день тому
Pulling The Fire Alarm At My School For The Last Time Ever For Fire Drill
Testing My Fire Alarm Systems | Fire Alarm, Generator, Emergency Light Monthly System June Testing
Переглядів 7 тис.21 день тому
Testing My Fire Alarm Systems | Fire Alarm, Generator, Emergency Light Monthly System June Testing
Fire alarm drill at elementary school
Переглядів 5 тис.28 днів тому
Fire alarm drill at elementary school
Installing Emergency Light In My Fire Alarm Panel Room | Power Goes Out Emergency Lights Turn On!
Переглядів 4,9 тис.Місяць тому
Installing Emergency Light In My Fire Alarm Panel Room | Power Goes Out Emergency Lights Turn On!
Fire Drill at High School | Pulling Fire Alarm Drill #5
Переглядів 8 тис.Місяць тому
Fire Drill at High School | Pulling Fire Alarm Drill #5
Is My Generator Wrong? Bonded Neutral Vs Floating neutral? Bonded in two different spots!
Переглядів 3,1 тис.Місяць тому
Is My Generator Wrong? Bonded Neutral Vs Floating neutral? Bonded in two different spots!
Installing A Red Fire Alarm Strobe Light On My Generator Building.
Переглядів 15 тис.Місяць тому
Installing A Red Fire Alarm Strobe Light On My Generator Building.
Elementary/middle school fire alarm drill
Переглядів 6 тис.Місяць тому
Elementary/middle school fire alarm drill
Setting Off Sidewall Fire Sprinkler Head | Testing Garage Sprinkler System Set Off Fire Alarm.
Переглядів 11 тис.Місяць тому
Setting Off Sidewall Fire Sprinkler Head | Testing Garage Sprinkler System Set Off Fire Alarm.
Power Outage Generator Test At High School | Real Power Loss Simulation Emergency Generator Test!
Переглядів 18 тис.Місяць тому
Power Outage Generator Test At High School | Real Power Loss Simulation Emergency Generator Test!
Fixing a problem with my back up generator. Homemade generator system update
Переглядів 3,6 тис.Місяць тому
Fixing a problem with my back up generator. Homemade generator system update
Setting Off Fire Alarm System HVAC Duct Detector With Smoke Machine Into Air Duct!
Переглядів 14 тис.Місяць тому
Setting Off Fire Alarm System HVAC Duct Detector With Smoke Machine Into Air Duct!
Accidentally set off security intrusion alarm system
Переглядів 9 тис.Місяць тому
Accidentally set off security intrusion alarm system
The Coolest Best Portable Battery Power Bank I've Ever Used (electronic nerdy-ness messing around)
Переглядів 1,8 тис.Місяць тому
The Coolest Best Portable Battery Power Bank I've Ever Used (electronic nerdy-ness messing around)
Setting off fire alarms by lighting fire alarm heat detector on fire!
Переглядів 15 тис.Місяць тому
Setting off fire alarms by lighting fire alarm heat detector on fire!
Testing Both My Fire Alarm Systems, Emergency Lighting And Backup Generator And UPS's | May testing
Переглядів 15 тис.Місяць тому
Testing Both My Fire Alarm Systems, Emergency Lighting And Backup Generator And UPS's | May testing
Testing Brand New Fire Alarm System Audible Devices | Notifier NFS2-3030 Verification Part 2 / Day 6
Переглядів 6 тис.2 місяці тому
Testing Brand New Fire Alarm System Audible Devices | Notifier NFS2-3030 Verification Part 2 / Day 6
Testing my backup generator night time power outage test
Переглядів 4,5 тис.2 місяці тому
Testing my backup generator night time power outage test
Setting Off Both Fire Alarm Systems At The Same Time | Garage & House
Переглядів 8 тис.2 місяці тому
Setting Off Both Fire Alarm Systems At The Same Time | Garage & House
Testing brand new fire alarm system install | Notifier NFS2-3030 verification
Переглядів 7 тис.2 місяці тому
Testing brand new fire alarm system install | Notifier NFS2-3030 verification
Replacing fire alarm backup batteries and battery sizing calculation for fire alarm system
Переглядів 4 тис.2 місяці тому
Replacing fire alarm backup batteries and battery sizing calculation for fire alarm system
Shed Fire Alarm System Install. House System Expansion! Installing Programming Testing Part 2
Переглядів 7 тис.2 місяці тому
Shed Fire Alarm System Install. House System Expansion! Installing Programming Testing Part 2
I wonder if there's a way you could have some light strip in the kitchen change to orange/yellow when the system goes into pre-alarm? I mean, it's not necessary at all. But it _would_ be cool.
5:50 This is too funny! Every time I watch this I always laugh at this part because you get so annoyed over a dog bark. I wouldn't get annoyed unless if a dog is barking so loud and obnoxiously. And that bark was pretty funny too. (But everyone is different I guess).
*I just had a fire drill at school today.*
In my personal opinion, pre-alarm shouldn’t be used because every second counts in a real fire and or smoke situation. I find it ridiculous that Disney World has pre-alarm set to 2 minutes on attractions but that’s just me lol
That's not how it works your set pre-alarm level is not a time delayed alarm. It's an entirely different set level below the alarm level it does not affect your alarm response time. You are talking about pre-signal which is entirely different.
at 3:15 is the door closer attached to the door thats its supposed to be closing and the door mounting location?!
I was going to recommend swapping the heads from the bedroom and the stairs to see if one head is less sensitive, but the explanation you made on the sensitivity setting makes sense. If they were set the same then I would try that.
20:34 My school has that same fire alarm
Like many commercial fire systems when a alarm goes off it automatically calls the fire department. Does your system call the fire department or do you have to call the fire department yourself?
It's a self monitored system
This is one hell of a middle school. The entire property just looks so good
Try putting an annunciator for the garage system next to the house front door pull.
I agree that smoke alarms are unreliable more often than they should be, so I also installed a fire alarm system in my house monitored by an American monitoring company, ADT. I don't recommend getting it monitored because it already sends emails and notifications to your phone without monitoring, and the monitoring fees are at least 100 USD each month, which is extremely expensive. Overall, the system is exceptionally high quality and has a pre-alarm to prevent false alarms. I have had the system for nine years, and it has picked up a real fire in an oven caused by debris being left in the stove, which got me and my family safely evacuated and quickly notified the fire department before the fire spread further. The system also does CO as well. Just yesterday, my house had a dangerous outlet that sparked so horrifically it split in half and crumbled into pieces, but I was much less worried even knowing there was an active fire hazard because of the fire alarm system. I encourage everyone who reads this to stay as safe as possible by at least getting residential smoke and co-detectors in recommended areas of the house. Stay safe and even safer with fire protection.
great video! im writing a mod for Minecraft (fabric 1.19.2) that adds some fire alarm devices and exit signs. i currently have a BG-12 pull station, a white exit sign, and a key for the pull station.
nice and nicely explained
Jaxon or what ever how you say his name
It sounds like the alarms went off to getther
Dog is going crazy
It's like last time in November it went off
When your going to start july testing
problay a brownout i live in tennseee so ya
A brown out is a reduced voltage this was two phases lost completely
@@nics-systems-electric ah ok, they look the same.
Nice video and nicely explained 😊, does Notifier/Honeywell make any multisensors ?
Yes they do
@@nics-systems-electricOh nice 😊, why did you not use them in the generator building?
@@The_FireAlarmGuy because I want smoke or heat to be able to set it off and not need both to be set of might be possible to separate but they are way to expensive anyway.
@@nics-systems-electricAh ok👍 😊
The cast iron skillet returns again, causing an alarm that isn't false and the system worked like how it should
Jackson: GRRRRRR me: be quiet lol
Nice! Soooo cool that i shows you the percentage of smoke in the smoke chamber on the announciator
You need to do July testing
Nice to see your system working as it should!
I think that it would have been concerning if it didn’t go off. The system was doing its job.
Yes I agree I can’t believe People would say it wasn’t doing it’s Job
Perfect system! Not only are low frequency sounders good for the rooms, but code 3 especially because I once saw you put them in continious, and they hurt my ears pretty bad, and horns (especially for me) are bad because they will increase panic attacks no matter if it is a system sensor horn or a Wheelock horn. Also I thought for a while that the sounders were horns but you didn't call them horns once.
I was actually going to ask you to test the pre- alarm feature of the smoke detectors in a monthly system test. Nice to see the system working and protecting your house. Great video! Keep up the good work!
fire
Nice video
At 5:45 I meant to say those devices in corridor and stairwell are less sensitive. Thanks for watching!
If i ready learn is i use 5v for safe
5 V won't be enough
@@nics-systems-electric like the Horing AHR-871 can use 5 v
Rip
You have to admire his idea even if it is very shaky. For a young person to have this kind of inventive idea is something. I hope he doesn't get killed first.
How long have you been working with electrical systems?
Your Channel Icon Is The Notifier Icon!
You guys aren’t required to have red painted boxes and conduit for fire alarm systems in Canada?
No
I'll collect bells
❤
my fire drill in pps 28: REEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE
It's good to see this series again I needed to eat something so thanks for teaching me
Will you take. A break for college 😊
I'm in college now
I'm just informing you that you can get a propane tank and have a truck fill it up whenever you need it. We have a 500-gallon propane tank that we get filled 2 or 3 times a year. We run our stove, oven, water heater, and heat.
Hello Nic, I just bought an emergency light and the wires are red and white. Red being 120AC and the white being Comm. How would I wire that?
Just the same but make sure the red is actually 120 and the unit has a nameplate for 120 because red could be 277 or 347
You need to do July testing
It’s not may it’s July
Huh
Lol
In regards to the issue of powering the dampers off the building AC supply and being reliant on a successful transfer to emergency power to ensure the damper opens I would say your best option would be to power it off DC from the generator battery. The datasheet of the LMB24-SR damper motor says it can accept 19.2 to 28.8 V DC so you could just use a little 12 V to 24 V DC-DC converter to power it from the generator starter battery, it's only 1.5 W when moving so the battery and maintenance charger could easy supply that. You should also be able to remove the relay by wiring it different, unfortunately at the moment I don't think you've wired it correctly. You seem to be applying 24 V AC across the Y and U terminals to open it, however only Y is used for control, U is an output for the position feedback signal. It previously opened when you connected it to the transformer because it was powering the Y control signal from the U output position signal through the winding of the transformer as you suspected. It goes to 50% because that's that point where the feedback signal matches the control voltage, likely about 5V. Also don't know about controlling it with 24 V directly, it likely does has input protection but it's not designed for continuously applying 24 V, just small transients, doing so will cause the internal protection components to overheat and fail over time. To solve this you can just use a 500 ohm resistor as the datasheet recommends, BELIMO even sells this as a pre-made heat shrunk cable, part number ZG-R01. But anyway this has been a cool project to follow!
I will have to look into it as that may be an auction power off the generators battery.